Self-rescue method of low magnetic force after maintenance of electromagnetic chuck
Time: 2023-10-15 Visit: 2,059 Type size

Magnetic chuck after the maintenance of the magnetic low reason for self-rescue, there are many enterprises and factories in order to save the cost of buying new magnetic chuck, will carry out their own magnetic chuck disassembly, self-maintenance, although at that time through their own exploration, the magnetic chuck to repair, but after not much time, the magnetic chuck has a problem, can not carry out normal work;

 

As the saying goes, smell the way has successively, the profession has specialized, here to describe is the best expression! Today, let Huigong magnetic industry Group electromagnetic chuck maintenance manufacturers tell you how to repair their own electromagnetic chuck, how to make their own electromagnetic chuck after maintenance can be like the original purchase of a new electromagnetic chuck, can work normally, to solve their own work problems, for this to give you the five steps of electromagnetic chuck maintenance:

 

Step 1. First, use a low-voltage test pen to change the switch of the electromagnetic sucker to see if there is a broken line or a place with poor contact. If the wire end of the electromagnetic sucker is found, it should be connected in time, and the place with poor contact should be re-pressed.

 

Step 2, use a low-voltage test pen to test the pile head under the spiral insurance of the lathe of the electromagnetic sucker, and check if it is the line of the phase insurance fuse, the phase insurance is generally not connected to the control loop of the two-phase 380v power supply, and the insurance needs to be replaced when the fuse is broken.

 

Step 3. Open the arc extinguishing cover of the electromagnetic suction cup controller. Manually close the contactor when the switch is off and the power supply is disconnected.

 

Step 4. In the case of disconnecting the power supply of the machine, check the main power line from the pile head under the contactor of the electromagnetic sucker to the access motor wiring frame, find out which power is burned off and reconnect the power.

 

Step 5. Open the electromagnetic sucker to check which wire connector is burned out. After finding out, re-weld the wire and lead out the wire.

 

The problem of the electromagnetic chuck is not terrible, terrible is that you disassemble and repair your own electromagnetic chuck, until the entire waste of your own electromagnetic chuck, through the steps I give you here today, so that you have a general maintenance direction for the electromagnetic chuck, and in order to enable you to understand the maintenance process more clearly, For everyone to sort out the electromagnetic chuck principle model diagram, and related electromagnetic chuck parameter table data, for reference only:

 